ÀÛµ¿ ¿Âµµ 0–50 ¡É (32–122 ¢µ)
ÀúÀå ¿Âµµ -40–70 ¡É (-40–158 ¢µ)
ÀÛµ¿ ½Àµµ Operating Humidity: 10–90% (À̽½ÀÌ ¸ÎÈ÷Áö ¾ÊÀ» °Í)
º¸°ü ½Àµµ Storage Humidity: 5–90% À̽½ÀÌ ¸ÎÈ÷Áö ¾ÊÀ» °Í
Çϵå¿þ¾î »ç¾ç
Ç¥ÁØ ¹× ÇÁ·ÎÅäÄÝ IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1x, IEEE 802.1p
ÀÎÅÍÆäÀ̽º • 8°³ÀÇ 10/100/1000 Mbps RJ45 Æ÷Æ® (Auto-Negotiation/Auto MDI/MDIX Áö¿ø)

• 2°³ÀÇ 100/1000 Mbps SFP ½½·Ô
³×Æ®¿öÅ© ¹Ìµð¾î • 10BASE-T: UTP/STP Ä«Å×°í¸® 3, 4, 5 ÄÉÀ̺í (ÃÖ´ë 100m)

• 100BASE-TX/1000Base-T: UTP/STP Ä«Å×°í¸® 5, 5e ¶Ç´Â ±× ÀÌ»óÀÇ ÄÉÀ̺í (ÃÖ´ë100m)

• 100BASE-FX: MMF, SMF

• 1000BASE-X: MMF, SMF
ÆÒ(Fan) ¼ö·® 1
¹°¸®ÀûÀÎ º¸¾È ¶ô Áö¿ø
Àü¿ø °ø±Þ 100-240V AC, 50/60Hz
PoE+ Æ÷Æ®(RJ45) • Ç¥ÁØ: 802.3at/af Áؼö

• PoE+ Ports: 8°³ Æ÷Æ®

• Àü¿ø °ø±Þ: 150W
PoE Æ÷Æ® (RJ45) • Standard: 802.3at/af compliant

• PoE+ Ports: 8 Ports

• PoE Power Budget: 150 W*
Å©±â ( °¡·Î x ¼¼·Î x ³ôÀÌ ) 11.6 x 7.1 x 1.7 in (294 x 180 x 44 mm)
¸¶¿îÆ® ·¢ ¸¶¿îÆ® °¡´É
ÃÖ´ë Àü·Â ¼Ò¸ð·® • 12.2 W (110 V / 60 Hz with no PD connected)

• 173.9 W (110 V / 60 Hz with 150 W PD connected)
ÃÖ´ë ¹æ¿­¼öÄ¡ • 41.63 BTU/h (with no PD connected)

• 539.35 BTU/h (with 150 W PD connected)
¼º´É
½ºÀ§Äª ¿ë·® 20 Gbps
ÆÐŶ Àü´Þ ¼Óµµ 14.9 Mpps
MAC ÁÖ¼Ò Å×À̺í 8K
ÆÐŶ ¹öÆÛ ¸Þ¸ð¸® 4.1 Mbit
Á¡º¸ ÇÁ·¹ÀÓ 9 KB
¼ÒÇÁÆ®¿þ¾î ±â´É
¼­ºñ½º Ç°Áú(QoS) • 802.1p CoS/ DSCP ¿ì¼± ¼øÀ§ Áö¿ø

• 8°³ÀÇ ¿ì¼± ¼øÀ§ Å¥

• ¿ì¼± ¼øÀ§ ½ºÄÉÁì ¸ðµå

- ¾ö°ÝÇÑ ¿ì¼± ¼øÀ§ (SP, Strict Pririty)

- °¡Áß ¶ó¿îµå ·Îºó (WRR, Weighted Round Robin)

• Å¥ °¡ÁßÄ¡ ¼³Á¤

• ´ë¿ªÆø Á¦¾î

- Port/Flow- ±â¹Ý ¼Óµµ Á¦¾î

• ÇÑÃþ ºÎµå·¯¿î ¼º´É

• Ç÷οì Á¦¾î ¾×¼Ç

- ¹Ì·¯(Áö¿øµÇ´Â ÀÎÅÍÆäÀ̽º·Î)

- ¸®´ÙÀÌ·ºÆ®(Áö¿øµÇ´Â ÀÎÅÍÆäÀ̽º·Î)

- ¼Óµµ Á¦ÇÑ

- QoS ¸®¸¶Å·

• Æødz(Storm) Á¦¾î

- ¿©·¯ Á¦¾î ¸ðµå(kbps/ratio/pps)

- ºê·Îµåij½ºÆ®/¸ÖƼij½ºÆ®/¹ÌÈ®ÀÎ-À¯´Ïij½ºÆ® Á¦¾î
L2 ±â´É • DHCP Relay

- DHCP VLAN Relay

• DHCP L2 Relay

• Link Aggregation

- Static link aggregation

- 802.3ad LACP

- Up to 8 aggregation groups and up to 8 ports

per group

• Spanning Tree Protocol

- 802.1D STP

- 802.1w RSTP

- 802.1s MSTP

- STP Security: TC Protect, BPDU Filter/Protect,

Root Protect

• Loopback Detection

• Flow Control

- 802.3x Flow Control

• Mirroring

- Port Mirroring

- CPU Mirroring

- One-to-One

- Many-to-One

- Flow-Based

- Ingress/Egress/Both

• Device Link Detect Protocol (DLDP)

• 802.1ab LLDP/ LLDP-MED
L2 ±â´É • ¸µÅ© ¾Ö±×¸®°ÔÀ̼Ç(Link Aggregation)

- Á¤Àû ¸µÅ© ¾Ö±×¸®°ÔÀ̼Ç

- ÃÖ´ë 8°³ ¾Ö±×¸®°ÔÀÌ¼Ç ±×·ì, °¢ ±×·ì ´ç ÃÖ´ë 8°³ÀÇ Æ÷Æ® Áö¿ø

- 802.3ad LACP

• ½ºÆÐ´× Æ®¸® ÇÁ·ÎÅäÄÝ

- 802.1D STP

- 802.1w RSTP

- 802.1s MSTP

- STP º¸¾È: ·çÇÁ¹é(Loop back) ŽÁö, TC º¸È£, BPDU ÇÊÅÍ/º¸È£, Root º¸È£

• ·çÇÁ¹é(Loopback) ŽÁö

• Ç÷οì Á¦¾î

- 802.3x Ç÷οì Á¦¾î

• ¹Ì·¯¸µ

- Æ÷Æ® ¹Ì·¯¸µ

- ÀÏ´ëÀÏ(One-to-One)

- ´Ù´ëÀÏ(Many-to-One)

- ÇÃ·Î¿ì ±â¹Ý

- ¼ö½Å/¼Û½Å/¼ö¼Û½Å

- CPU ¹Ì·¯¸µ

• ÀåÄ¡ ¸µÅ© °¨Áö ÇÁ·ÎÅäÄÝ(DLDP, Device Link Detect Protocol)
L2 ¸ÖƼij½ºÆ® • 512 IPv4,IPv6 °øÀ¯ ¸ÖƼij½ºÆ® ±×·ì

• IGMP ½º´©ÇÎ

- IGMP v1/v2/v3 ½º´©ÇÎ

- Fast Leave

- IGMP ½º´©ÇÎ Äõ¸®¾î(Snooping Querier)

- IGMP ÀÎÁõ

- Á¤Àû ±×·ì ¼³Á¤

• MLD ½º´©ÇÎ

- MLD v1/v2 ½º´©ÇÎ

- Fast Leave

- MLD ½º´©ÇÎ Äõ¸®¾î(Snooping Querier)

- Á¤Àû ±×·ì ¼³Á¤

• ¸ÖƼij½ºÆ® VLAN µî·Ï

• ¸ÖƼij½ºÆ® ÇÊÅ͸µ
IPv6 Áö¿ø • IPv6 µà¾ó IPv4/IPv6

• Multicast Listener Discovery(MLD) ½º´©ÇÎ

• IPv6 ÀÌ¿ô Ž»ö(ND, Neighbor Discovery)

• °æ·Î ÃÖ´ë Àü¼Û ´ÜÀ§(Path MTU) Ž»ö

• ÀÎÅÍ³Ý Á¦¾î ¸Þ½ÃÁö ÇÁ·ÎÅäÄÝ(ICMP, Internet Control Message Protocol) ¹öÀü 6

• TCPv6/UDPv6

• IPv6 Àû¿ë

- DHCPv6 Ŭ¶óÀ̾ðÆ®

- Ping6

- Tracert6

- Telnet(v6)

- IPv6 SNMP

- IPv6 SSH

- IPv6 SSL

- Http/Https

- IPv6 TFTP
VLAN • VLAN ±×·ì

- ÃÖ´ë. 4K VLAN ±×·ì

• 802.1Q tag VLAN

• MAC VLAN: 12 Entries

• ÇÁ·ÎÅäÄÝ VLAN

• GVRP

• À½¼º VLAN
¾×¼¼½º ÄÁÆ®·Ñ ¸®½ºÆ® • ÃÖ´ë 230 Ç׸ñ Áö¿ø

• ½Ã°£ ¹üÀ§ ¼³Á¤

- ŸÀÓ ½½¶óÀ̽º(Time Slice)

- ÁÖ°£ ½Ã°£ ¹üÀ§

- Àý´ë(Absolute) ½Ã°£ ¹üÀ§

- ÈÞÀÏ

• ½Ã°£ ±â¹Ý ACL

• MAC ACL

- Ãâ¹ßÁö MAC

- µµÂøÁö MAC

- VLAN ID

- »ç¿ëÀÚ ¿ì¼± ¼øÀ§

- ÀÌ´õ³Ý À¯Çü

• IP ACL

- Ãâ¹ßÁö IP

- ¸ñÀûÁö IP

- IP ÇÁ·ÎÅäÄÝ

- TCP Ç÷¡±×

- TCP/UDP ¸ñÀûÁö Æ÷Æ®

- TCP/UDP µµÂøÁö Æ÷Æ®

- DSCP/IP TOS

• IPv6 ACL

• °áÇÕµÈ ACL

• ±ÔÄ¢ ±â¹Ý Çൿ

- Çã¿ë/°ÅÀý

• Á¤Ã¥ ±â¹Ý Çൿ

- ¹Ì·¯

- ¼Óµµ Á¦ÇÑ

- ¸®´ÙÀÌ·ºÆ®

- QoS ¸®¸¶Å·

• ACL ±ÔÄ¢ ¹ÙÀεù

- Æ÷Æ® ¹ÙÀεù

- VLAN ¹ÙÀεù
º¸¾È • AAA

• 802.1X

- Port based authentication

- MAC(Host) based authentication

- Authentication Method includes PAP/EAP-MD5/EAP-TLS/EAP-TTLS/EAP-PEAP

- MAB

- Guest VLAN

- Support Radius authentication and accountability

• IP/IPv6-MAC Binding

- 512 Binding Entries

- DHCP Snooping

- DHCPv6 Snooping

- ARP Inspection

- ND Detection

• IP Source Gurad

- 253 Entries

- Source IP+Source MAC

• IPv6 Source Gurad

- 183 Entries

- Source IPv6 Address+Source MAC

• DoS Defend

• Static/Dynamic/Permanent Port Security

- Up to 64 MAC addresses per port

• Broadcast/Multicast/Unicast Storm Control

- kbps/ratio/pps control mode

• Port Isolation

• Secure web management through HTTPS with SSLv3/TLS1.2

• Secure Command Line Interface (CLI) management with SSHv1/SSHv2

• IP/Port/MAC based access control
IPv6 • IPv6 Static Routing and ACL

• IPv6 Dual IPv4/IPv6

• IPv6 Interface

• Multicast Listener Discovery (MLD) Snooping

• IPv6 neighbor discovery (ND)

• Path maximum transmission unit (MTU) discovery

• Internet Control Message Protocol (ICMP)

version 6

• TCPv6/UDPv6

• IPv6 applications

- DHCPv6 Client

- Ping6

- Tracert6

- Telnet(v6)

- IPv6 SNMP

- IPv6 SSH

- IPv6 SSL

- Http/Https

- IPv6 TFTP
°í±Þ ±â´É • Automatic Device Discovery

• Batch Configuration

• Batch Firmware Upgrading

• Intelligent Network Monitoring

• Abnormal Event Warnings

• Unified Configuration

• Reboot Schedule
MIBs • MIB II (RFC1213)

• ÀÎÅÍÆäÀ̽º MIB (RFC2233)

• ÀÌ´õ³Ý ÀÎÅÍÆäÀ̽º MIB (RFC1643)

• ºê¸´Áö MIB (RFC1493)

• P/Q-ºê¸´Áö MIB (RFC2674)

• RMON MIB (RFC2819)

• RMON2 MIB (RFC2021)

• Radius °èÁ¤ Ŭ¶óÀ̾ðÆ® MIB (RFC2620)

• Radius ÀÎÁõ Ŭ¶óÀ̾ðÆ® MIB (RFC2618)

• Remote Ping, Traceroute MIB (RFC2925)

• TP-Link »ç¼³ MIB Áö¿ø
°ü¸®
Omada ¾Û Áö¿ø
Áß¾Ó ÁýÁᫎ °ü¸® • Omada Ŭ¶ó¿ìµå ±â¹Ý ÄÁÆ®·Ñ·¯

• Omada Çϵå¿þ¾î ÄÁÆ®·Ñ·¯ (OC300)

• Omada Çϵå¿þ¾î ÄÁÆ®·Ñ·¯ (OC200)

• Omada ¼ÒÇÁÆ®¿þ¾î ÄÁÆ®·Ñ·¯
Ŭ¶ó¿ì½º ¾×¼¼½º Áö¿ø (OC300, OC200, Omada Ŭ¶ó¿ìµå ±â¹Ý ÄÁÆ®·Ñ·¯ ȤÀº Omada ¼ÒÇÁÆ®¿þ¾î ÄÁÆ®·Ñ·¯¸¦ ÅëÇØ)
Á¦·Î ÅÍÄ¡ ÇÁ·ÎºñÀú´× Yes. Requiring the use of Omada Cloud-Based Controller (Supported by TL-SG2210MP v1, v3 and above, while is not supported by TL-SG2210MP v2)
°ü¸® ±â´É • Web ±â¹Ý GUI ¹× CLI °ü¸®

• SNMPv1/v2c/v3

• SNMP Trap/Inform

• RMON (1,2,3,9 ±×·ì)

• SDM ÅÛÇø´

• DHCP/BOOTP Ŭ¶óÀ̾ðÆ®

• µà¾ó À̹ÌÁö, µà¾ó ¼³Á¤

• CPU ¸ð´ÏÅ͸µ

• ÄÉÀ̺í Áø´Ü

• EEE

• ½Ã½ºÅÛ ·Î±×

• 802.1ab LLDP/ LLDP-MED
±âŸ
ÀÎÁõ CE, FCC, RoHS
±¸¼ºÇ° • TL-SG2210MP

• Power Cord

• Installation Guide

• Rackmount Kit

• Rubber Feet

¿î¿µ üÁ¦ Microsoft¢ç Windows¢ç 98SE, NT, 2000, XP, Vista¢â or Windows 7/8/10, MAC¢ç OS, NetWare¢ç, UNIX¢ç or Linux.
»ç¿ë ȯ°æ • ÀÛµ¿ ¿Âµµ: 0–40 ¡É (32–104 ¢µ);

• º¸°ü ¿Âµµ: -40–70 ¡É (-40–158 ¢µ)

• ÀÛµ¿ ½Àµµ: 10–90% »ó´ë½Àµµ (ºñÀÀÃà)

• º¸°ü ½Àµµ: 5–90% »ó´ë½Àµµ (ºñÀÀÃà)

## ¸ð¹ÙÀÏ(½º¸¶Æ®Æù)·Î »óÇ°Á¤º¸ È®Àνà »ó¼¼Á¤º¸°¡ ¾È º¸ÀÏ ¼ö ÀÖÀ¸´Ï ¼¼ºÎÁ¤º¸ È®ÀÎ ÇÊ¿ä½Ã PCȯ°æ¿¡¼­ ºÁÁÖ¼¼¿ä.

## Á¦Á¶»çÀÇ »çÁ¤¿¡ ÀÇÇØ »ö»óÀ̳ª µðÀÚÀÎ/»ç¾çÀÌ º¯°æ µÉ ¼ö ÀÖÀ¸¹Ç·Î »ó¼¼ »ç¾ç ÇÊ¿ä½Ã º°µµ¹®ÀÇ!!

## ·¢(Åë½Å·¢/¼­¹ö·¢Àº) ³³±â°¡ ¹ßÁÖÈÄ2~4ÀÏÁ¤µµ ¼Ò¿äµË´Ï´Ù.Á¤È®Çѳ³±âÀüÈ­¹®ÀÇ!!##¹«°Å¿î ·¢ ¹è¼ÛÀº 1Ãþ±îÁö¸¸ ¹è¼ÛÇص帳´Ï´Ù.##

## CD°ü ¹× ÈÄ·º½ÃºíµîÀº ¹è¼ÛÈÄ Æ÷Àå»óÅ°¡ ³ªºüÁ® ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù.

¡ØÁ¤È®ÇÑ Á¦Ç°»ç¾ç ¿ä±¸½Ã º°µµ¹®ÀÇ ÁÖ¼¼¿ä.»óÇ°¼³¸í¿À·ù°¡ ÀÖÀ» ¼ö ÀÖÀ¸´Ï º°µµ ¹®ÀÇ ÁÖ¼¼¿ä.¡Ø

±æÀ̳ª ºÎÇÇ°¡ Å« Á¦Ç°°°Àº°æ¿ì(¸ôµå,Åë½ÅÀÚÀç·ùµî) ¹­À½¹è¼ÛÀÌ µÇÁö ¾Ê±â ¶§¹®¿¡ ±âº» ¿îÀÓ

2,500¿ø~5,000¿ø ¹Ì¸¸À¸·Î °è»êµÉ°æ¿ì ³ª¸ÓÁö´Â ÂøºÒ·Î ¹ß¼ÛµË´Ï´Ù. Â÷¾×µîÀº Àû¸³ ¹× ȯºÒÇØ µå¸³´Ï´Ù.

Äü/È­¹° ¿äû½Ã ÂøºÒ·Î °áÁ¦ÇØ ÁÖ¼¼¿ä.


°ü·Ã»óÇ°
À§ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
»óÇ°Èıâ
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
 
»óÇ°¹®ÀÇ
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥ ºñ°í
ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
  »óÇ°¹®ÀÇÇϱâ
¹ÝÇ°¹×±³È¯
-°í°´ º¯½É¿¡ ÀÇÇÑ ¹ÝÇ°½Ã ¿Õº¹ Åùèºñ º»ÀÎ ºÎ´ãÇÏ¼Å¾ß Çϸç 1ÁÖ(7ÀÏ)À̳» ÇϼžßÇÕ´Ï´Ù.ÀÌ ÈÄ ¹ÝÇ°ºÒ°¡.
-¹ÝÇ°½Ã Á¦Ç°ÀÌ ¹Ú½º³ª Æ÷ÀåÀÌ ÈѼÕÀÌ µÈ °æ¿ì ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÏ¸ç ¹ÝÇ°Àü »ó´ãÈÄ ¹ÝÇ°¿äûÇØÁÖ¼¼¿ä.
-ÀϺΠÁ¦Ç°Àº °³ºÀ½Ã ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÒ ¼öµµ ÀÖ½À´Ï´Ù.(Æ÷Àå¹×¹Ì°³ºÀ½ºÆ¼Ä¿ºÎÂøÁ¦Ç°)
-¹ÝÇ°½Ã °ÑÆ÷ÀåÀÌ ¾Æ´Ñ Á¦Ç°¿¡ Åùè¼ÛÀåÀ» ºÙ¿©¼­ ¹Ý¼ÛÇÒ °æ¿ì ¹ÝÇ° ¾ÈµË´Ï´Ù.
-Åë½Å·¢/¼­¹ö·¢Àº ¿î¼ÛÁß ÆÄ¼Õ¹× Á¦Ç°ÀÌ ÈѼյǼ­ ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù. (µðÆ÷±×,SGÁ¤º¸ ¹ÝÇ°¾ÈµÊ)

 -ÄÉÀÌºí ¹ÌÅÍ(M)´ÜÀ§·Î ÆǸÅÇÏ´Â Á¦Ç°Àº ÄÆÆÃÇؼ­ ÆǸÅÇÏ´Â Á¦Ç°À¸·Î ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÕ´Ï´Ù.
-Á¦À۵ǴÂÁ¦Ç°¹ÝÇ°ºÒ°¡(ÄÉÀ̺íÄÆÆÃÁ¦Ç°/Á¦ÀÛÁ¦Ç°/´ÜÀÚÇÔSUSÁ¦Ç°±º/±âŸÁ¦ÀÛ Á¦Ç°±º)

 -ÀúÀåÀåÄ¡(NAS/DASµî)Á¦Ç°±º HDDÁ¶¸³½Ã ÁÖ¹®ÈÄ ¹ÝÇ°/Ãë¼Ò ºÒ°¡´ÉÇÕ´Ï´Ù.

 -Á¦Ç° ȣȯ¼ºÀ¸·Î ¾ÈµÇ´Â°ÍÀ¸·Î ÀÎÇÑ ¹ÝÇ°ºÒ°¡!!(ÀϺÎÁ¦Ç°Á¦¿Ü) »çÀü ȣȯ¼º¹®ÀÇ ¹× üũ !!


¹è¼Û¾È³»

- ÁÖ¹®Á¢¼ö ¸¶°¨½Ã°£ ¿ÀÈÄ4½Ã(ÀÚ»ç Á¦Ç° ¿ÀÈÄ5½Ã)(Á¦ÀÛ»óÇ°: ¿ÀÈÄ2½Ã)ÀÔ´Ï´Ù.

- ´çÀÏ Ãâ°í¸¦ ÇؾßÇÏ´Â °æ¿ì º°µµ ÀüÈ­¸¦ ÁÖ¼¼¿ä.

- °áÁ¦ÈÄ 2~5ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
- ±âº» Åùè¹ß¼ÛÀº ·ÎÁ¨Åùè/°æµ¿Åùè/´ë½ÅÅù踦 ÀÌ¿ëÇÏ¿© ¹ß¼ÛÇÕ´Ï´Ù.
- Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.
- Ãß°¡ ¿îÀÓÁö¿ª(Á¦ÁÖµµ,µµ¼­»ê°£Áö¿ª)Àº ±âº»¿îÀÓÀ¸·Î °áÁ¦½Ã ¿îÀÓ µ¿ºÀÇÏ¿© ÂøºÒ ¹ß¼ÛµË´Ï´Ù.

- µðÆ÷±×·¢ÀÇ °æ¿ì µðÆ÷±×¹°·ù¿¡¼­ Á÷Á¢¹è¼ÛµÇ¸ç ¹ßÁֽà 3~4ÀÏÁ¤µµ ¼Ò¿äµË´Ï´Ù.

È­¹°Åù踦 ÀÌ¿ëÇÑ°æ¿ì ÂøºÒ¹ß¼ÛµÇ¸ç Æļսà ¼ÒºñÀÚÃ¥ÀÓÀÔ´Ï´Ù.(°æµ¿/´ë½Å Ã¥ÀÓx)


°áÁ¦¾È³»

ÀÎÅÍ³Ý ºê¶ó¿ìÀú(Exploer)¹öÀüÀÌ 8ÀÌÇÏÀΰæ¿ì º¸¾È»ó °áÁ¦°¡ ¾ÈµÉ¼ö ÀÖÀ¸´Ï »óÀ§¹öÀüÀ¸·Î ¾÷µ¥ÀÌÆ® ÇØÁÖ¼¼¿ä.
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.

Á¦Ç° Ç°Àý·ÎÀÎÇØ Àû¸³±Ý ¿äû½Ã ¼¼±Ý°è»ê¼­´Â Àû¸³±ÝÀ» Á¦¿ÜÇÏ°í °è»ê¼­ ¹ßÇàµË´Ï´Ù.



 

ȸ»ç¼Ò°³ ÀÌ¿ë¾à°ü °³ÀÎÁ¤º¸Ãë±Þ¹æħ °í°´¼¾ÅÍ

»óÈ£¸í : ÁÖ½Äȸ»ç À¯ºñÅ¥³Ý
»ç¾÷ÀÚµî·Ï¹øÈ£ : 876-81-02587 / ´ëÇ¥ÀÌ»ç : ÀÌÀç½Ä / »ç¾÷ÀÚÁ¤º¸ È®ÀÎ / ¿¡½ºÅ©·Î°¡ÀÔ»ç½ÇÈ®Àμ­ È®ÀÎ
»ç¾÷ÀÚ¼ÒÀçÁö : ¼­¿ï½Ã ¿ë»ê±¸ ûÆÄ·Î113-6,³Ø¼­½º¹ë¸® 905È£ / Åë½ÅÆǸž÷½Å°í : Á¦2022-¼­¿ï¿ë»ê-1075È£
´ëÇ¥ÀüÈ­ : 02-711-0056 / Fax : 02-6280-6941 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ ÀÌÀç½Ä / ubiqnet@ubiqnet.co.kr